Fiber Reinforced Plastics/Composites ›› 2016, Vol. 0 ›› Issue (4): 21-25.

• BASIC STUDY • Previous Articles     Next Articles

THE EFFECTS OF ELECTRIC-THERMAL LOAD ON THE SHEAR PROPERTYOF THE CFRP SINGLE-LAP JOINT AFTER REPAIR

ZHU Chen1, ZHANG Jun1, LU Peng-cheng1, WANG Tao2   

  1. 1.Tianjin Key Laboratory for Civil Aircraft Airworthiness and Maintenance,Civil Aviation University of China, Tianjin 300300, China;
    2.Guangzhou Aircraft Maintenance Engineering Co., Ltd., Guangzhou 510470, China
  • Received:2015-11-10 Online:2016-04-28 Published:2016-04-28

Abstract: Carbon fiber resin matrix composite material is widely applied in the field of aviation. It has become the norm of the aircraft structural repair. The electric-thermal load was studied in the paper and was performed on the CFRP single-lap joint after wet lay up repair. The surface temperature field of single-lap joint and the resistance of sample were measured by the self-devised damage test device. The change rules of temperature and resistance under different current applications have been investigated. The scanning electron microscope was used to analyze the changes of surface morphology after shear failure. It demonstrated that shear strength slight increases under low electric current since post curing of resin. Higher current application has a detrimental effect on the properties of the joint. Shear strength decreases under higher electric currents since high temperature can induce interfacial damage of joint.

Key words: CFRP repair, single-lap joint, electric-thermal load, shear strength

CLC Number: