STUDY ON LIMIT AXIAL-LOAD RATIO OF PVC-FRP CONFINED REINFORCED CONCRETE COLUMN

YU Feng1,2, NIU Di-tao2*   

  1. 1.School of Civil Engineering, Anhui University of Technology, Ma′anshan 243002, China;
    2.School of Civil Engineering, Xi′an University of Architecture and Technology, Xi′an 710055, China
  • Received:2017-02-03 Online:2018-02-28 Published:2018-02-28

Abstract: The mechanical behavior is analyzed according to the stress-strain relationship of PVC-FRP confined reinforced concrete column. Based on the equilibrium condition of large and small eccentric limit compression, the basic assumptions for limit axial-load ratio of PVC-FRP confined reinforced concrete column are proposed, and then a calculating method of limit axial-load ratio is derived. It is shown that the limit axial-load ratio of PVC-FRP confined reinforced concrete column decreases with the increasing hoop spacing of CFRP strips. The limit axial-load ratio of PVC-FRP confined reinforced concrete column is greatly improved compared with that of reinforced concrete column.

Key words: PVC-FRP tube, axial-load ratio, concrete column, bearing capacity, confinement