复合材料科学与工程 ›› 2025, Vol. 0 ›› Issue (11): 122-130.DOI: 10.19936/j.cnki.2096-8000.20251128.015

• 工程应用 • 上一篇    下一篇

FRP网格增强纤维混凝土夹芯复合墙板性能分析

成能名, 张耀林*, 常明媛, 张蓉   

  1. 中建科工集团有限公司 华东大区,深圳 518054
  • 收稿日期:2024-09-18 出版日期:2025-11-28 发布日期:2025-12-24
  • 通讯作者: 张耀林(1978—),男,学士,正高级工程师,研究方向为装配式钢结构建筑及智能建造技术研究与实践应用,zhangyaolin@cscec.com。
  • 作者简介:成能名(1978—),男,学士,高级工程师,研究方向为装配式钢结构建筑及智能建造技术研究与实践应用。

Performance analysis of FRP grid reinforced fiber concrete sandwich composite wall panels

CHENG Nengming, ZHANG Yaolin*, CHANG Mingyuan, ZHANG Rong   

  1. East China Region, China Construction Science & Industry Corporation Ltd., Shenzhen 518054, China
  • Received:2024-09-18 Online:2025-11-28 Published:2025-12-24

摘要: 为了探究适用于装配式钢结构建筑的轻质高强、保温性好的新型墙板材料与结构体系,本文提出了一种新型纤维增强聚合物(Fiber Reinforced Polymer,FRP)网格增强纤维混凝土夹芯复合墙板,简称纤维网格增强混凝土(FRP Grid Reinforced Concrete,FGRC)夹芯复合墙板。为了研究FGRC夹芯复合墙板的弯曲性能及其破坏形态,设计并开展了2块长度为4 m、宽度为3 m、厚度分别为100 mm和150 mm的FGRC夹芯复合墙板的弯曲性能试验研究。试验结果表明,FGRC夹芯复合墙板主要以弯曲破坏为主,界面连接性能优异,其抗弯极限荷载可达3.11 kN/m2、4.05 kN/m2,极限耐火时间分别为1.1 h、1.5 h,结构热阻分别为1.41 (m2·K)/W、1.72 (m2·K)/W,空气计权隔声量及频谱修正量分别为39(-2;-3) dB、39(0;-2) dB。综合来看,该墙板具有较好的应用价值。

关键词: 纤维增强聚合物网格, 纤维网格增强混凝土, 复合墙板, FRP连接件, 性能试验, 受力性能

Abstract: To explore new wall panel materials and structural systems that are lightweight, high-strength, and have good thermal insulation properties suitable for prefabricated steel structure buildings, a new type of FRP grid reinforced fiber concrete sandwich composite wall panel was proposed in this paper, referred to as an FGRC sandwich composite wall panel. To study the flexural performance and failure modes of the FGRC sandwich composite wall panels, bending performance tests were designed and conducted on two FGRC sandwich composite wall panels with dimensions of 4 m×3 m and thicknesses of 100 mm and 150 mm respectively. The test results show that the main failure mode of the FGRC sandwich composite wall panels is flexural failure, with excellent interface connection performance. The ultimate flexural load capacity can reach up to 3.11 kN/m2 and 4.05 kN/m2. The ultimate fire resistance times are 1.1 hours and 1.5 hours, and the structural thermal resistances are 1.41 (m2·K)/W and 1.72 (m2·K)/W, respectively. The air-borne sound insulation and frequency correction amounts are 39(-2;-3) dB and 39(0;-2) dB, respectively. Overall, this wall panel shows significant application value.

Key words: fiber reinforced polymer grid, fiber grid reinforced concrete (FGRC), composite wall panel, FRP connectors, performance testing, load-bearing performance